net: lantiq: lantiq_xrx200: Move clock prepare to probe function
The switch and the MAC are in one IP core and they use the same clock signal from the clock generation unit. Currently the clock architecture in the lantiq SoC code does not allow to easily share the same clocks, this has to be fixed by switching to the common clock framework. As a workaround the clock of the switch and MAC should be activated when the MAC gets probed and only disabled when the MAC gets removed. This way it is ensured that the clock is always enabled when the switch or MAC is used. The switch can not be used without the MAC. This fixes a data bus error when rebooting the system and deactivating the switch and mac and later accessing some registers in the cleanup while the clocks are disabled. Fixes: fe1a5642 ("net: lantiq: Add Lantiq / Intel VRX200 Ethernet driver") Signed-off-by: Hauke Mehrtens <hauke@hauke-m.de> Signed-off-by: David S. Miller <davem@davemloft.net>