[media] cec: poll should check if there is room in the tx queue

For POLLOUT poll only checked if the adapter was configured, not
if there was room in the transmit queue. Add that check.
Signed-off-by: default avatarHans Verkuil <hans.verkuil@cisco.com>
Signed-off-by: default avatarMauro Carvalho Chehab <mchehab@s-opensource.com>
parent 83505028
......@@ -52,7 +52,8 @@ static unsigned int cec_poll(struct file *filp,
if (!devnode->registered)
return POLLERR | POLLHUP;
mutex_lock(&adap->lock);
if (adap->is_configured)
if (adap->is_configured &&
adap->transmit_queue_sz < CEC_MAX_MSG_TX_QUEUE_SZ)
res |= POLLOUT | POLLWRNORM;
if (fh->queued_msgs)
res |= POLLIN | POLLRDNORM;
......