Commit c7d18867 authored by Hans de Goede's avatar Hans de Goede Committed by Mauro Carvalho Chehab

[media] pwc: Also set alt setting to alt0 when no error occured

isoc_cleanup contains a check to not set the altsetting to alt0 when
the device was unplugged, but the check currently is buggy, and causes
the alt setting to only be set to 0 if an error occured while streaming.
Signed-off-by: default avatarHans de Goede <hdegoede@redhat.com>
Signed-off-by: default avatarMauro Carvalho Chehab <mchehab@redhat.com>
parent 3751e288
......@@ -957,7 +957,7 @@ void pwc_isoc_cleanup(struct pwc_device *pdev)
/* Stop camera, but only if we are sure the camera is still there (unplug
is signalled by EPIPE)
*/
if (pdev->error_status && pdev->error_status != EPIPE) {
if (pdev->error_status != EPIPE) {
PWC_DEBUG_OPEN("Setting alternate interface 0.\n");
usb_set_interface(pdev->udev, 0, 0);
}
......
Markdown is supported