clocksource: samsung_pwm_timer: Correct definition of AUTORELOAD bit
PWM channel 4 has its autoreload bit located at different position. This patch fixes the driver to account for that. This fixes a problem with the clocksource hanging after it overflows because it is not reloaded any more. Signed-off-by:Tomasz Figa <tomasz.figa@gmail.com> Reviewed-by:
Sylwester Nawrocki <s.nawrocki@samsung.com> Tested-by:
Heiko Stuebner <heiko@sntech.de> Tested-by:
Mark Brown <broonie@linaro.org> Tested-by:
Sylwester Nawrocki <sylvester.nawrocki@gmail.com> Acked-by:
Arnd Bergmann <arnd@arndb.de>
Showing