phy: exynos-mipi-video: Use consistent method to address phy registers
Exynos4 MIPI phy registers are defined with macro calculating the offset for given phyN. Use the same method for Exynos5420 to be consistent. Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org> Reviewed-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com> Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com>