spi/pl022: Fix range checking for bits per word
pl022 ssp controller supports word lengths from 4 to 16 (or 32) bits. Currently implemented checks were incorrect. It has following check if (pl022->vendor->max_bpw >= 32) which must be checking for <=. Also error print message is incorrect, that prints "range is from 1 to 16". Fix both these issues. Signed-off-by: Vinit Shenoy <vinit.shenoy@st.com> Acked-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Grant Likely <grant.likely@secretlab.ca>
Showing
Please register or sign in to comment