Input: wm831x-ts - fix races with IRQ management
If the WM831x pen down and data IRQs run in parallel it is possible for the data and pen down IRQs to deadlock themselves as one is part way through disabling its operation while the other is part way through enabling. Fix this by always disabling the pen down interrupt while data is active and vice versa. When a changeover is required we disable the IRQ that is to be stopped then schedule work that will enable the new IRQ. We need to handle the data flow in the data IRQ as the readback from the device needs to be ordered correctly with the IRQ for robust operation. This also fixes an issue when using the built in IRQs due to enable_irq() not being valid from interrupt context on an interrupt controller with bus operations like the built in IRQ controller - this issue may also have affected other interrupt controllers. We can't rely on having the data and pen down IRQs available via GPIOs on the CPU on every system. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Dmitry Torokhov <dtor@mail.ru>