- 17 Oct, 2013 5 commits
-
-
Rashika Kheria authored
The patch fixes the following checkpatch.pl warning in conrpc.c- WARNING: space prohibited between function name and open parenthesis '(' Signed-off-by: Rashika Kheria <rashika.kheria@gmail.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Teodora Baluta authored
This patch fixes the following type of sparse warnings: drivers/staging/rtl8192u/ieee80211/ieee80211_tx.c:247:17: warning: incorrect type in argument 2 (different base types) drivers/staging/rtl8192u/ieee80211/ieee80211_tx.c:247:17: expected restricted gfp_t [usertype] flags drivers/staging/rtl8192u/ieee80211/ieee80211_tx.c:247:17: got int [signed] gfp_mask Signed-off-by: Teodora Baluta <teobaluta@gmail.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Teodora Baluta authored
These functions are already marked extern in the header file drivers/staging/rtl8192u/r819xU_phy.c:1716:13: warning: function 'InitialGainOperateWorkItemCallBack' with external linkage has definition drivers/staging/rtl8192u/r819xU_cmdpkt.c:497:12: warning: function 'cmpk_message_handle_rx' with external linkage has definition Signed-off-by: Teodora Baluta <teobaluta@gmail.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Rashika Kheria authored
This patch removes unused function 'RFbShutDown' from file rf.c Signed-off-by: Rashika Kheria <rashika.kheria@gmail.com> Reviewed-by: Josh Triplett <josh@joshtriplett.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Rashika Kheria authored
This patch fixes the following Sparse Warnings in rf.c: drivers/staging/vt6655/rf.c:58:21: warning: symbol 'dwAL2230InitTable' was not declared. Should it be static? drivers/staging/vt6655/rf.c:76:21: warning: symbol 'dwAL2230ChannelTable0' was not declared. Should it be static? drivers/staging/vt6655/rf.c:93:21: warning: symbol 'dwAL2230ChannelTable1' was not declared. Should it be static? drivers/staging/vt6655/rf.c:110:15: warning: symbol 'dwAL2230PowerTable' was not declared. Should it be static? drivers/staging/vt6655/rf.c:180:21: warning: symbol 'dwAL7230InitTable' was not declared. Should it be static? drivers/staging/vt6655/rf.c:203:21: warning: symbol 'dwAL7230InitTableAMode' was not declared. Should it be static? drivers/staging/vt6655/rf.c:222:21: warning: symbol 'dwAL7230ChannelTable0' was not declared. Should it be static? drivers/staging/vt6655/rf.c:288:21: warning: symbol 'dwAL7230ChannelTable1' was not declared. Should it be static? drivers/staging/vt6655/rf.c:352:21: warning: symbol 'dwAL7230ChannelTable2' was not declared. Should it be static? drivers/staging/vt6655/rf.c:431:6: warning: symbol 's_bAL7230Init' was not declared. Should it be static? drivers/staging/vt6655/rf.c:474:6: warning: symbol 's_bAL7230SelectChannel' was not declared. Should it be static? drivers/staging/vt6655/rf.c:634:6: warning: symbol 'RFbAL2230Init' was not declared. Should it be static? drivers/staging/vt6655/rf.c:681:6: warning: symbol 'RFbAL2230SelectChannel' was not declared. Should it be static? Signed-off-by: Rashika Kheria <rashika.kheria@gmail.com> Reviewed-by: Josh Triplett <josh@joshtriplett.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
- 16 Oct, 2013 35 commits
-
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Use unsigned types consistently for handling comedi sample data and also for the USB data buffers. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Use unsigned types consistently for handling comedi sample data and also for the USB data buffers. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Use unsigned types consistently in the "s626" module when dealing with sample values. Rewrite `s626_reg_to_uint()` as it can be done with a one-liner. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Use unsigned types for sample value manipulations in the "rtd520" driver for consistency. Also replace the hand-coded munging of 2's complement sample values with calls to `comedi_offset_munge()` and AND with `s->maxdata` to strip off any extra sign bits. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change `daqp_interrupt()` to use unsigned sample values for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change `pcmuio_handle_intr_subdev()` in the "pcmuio" module to use unsigned sample values for consistency. Also, make the order in which `pcmuio_handle_intr_subdev()` writes the two sample values (each actually containing up to 16 1-bit sample values) independent of the host byte ordering. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change `interrupt_pcmmio()` and `ai_rinsn()` in the "pcmmio" module to use unsigned sample values for consistency. Also, make the order in which `interrupt_pcmmio()` writes the two sample values (each actually containing up to 16 1-bit sample values) independent of the host byte ordering. Note that this module is a mess, so please excuse the checkpatch warnings. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change the interrupt data transfer functions in the "pcl818" module to use unsigned types for consistency. Also remove the `short *ai_data` member of `struct pcl818_private` as it is only assigned to and otherwise unused. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change the "pcl816" module to use unsigned types to handle samples for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change `transfer_from_dma_buf()` and `interrupt_pcl812_ai_dma()` in the "pcl812" module to use `unsigned short` sample values for consistency. Also remove the `short *ai_data` member of `struct pcl812_private` as it is only assigned to. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Don't cast the sample value parameter of `comedi_buf_put()` to `short`, particularly as it has now been changed to `unsigned short`. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change `nidio_interrupt()` to use unsigned types for sample values (actually bit-vectors of 1-bit sample values) instead of signed types. Also rename the `AuxData` variable to `auxdata` and change it from `long` to `unsigned int` as it only needs to hold a 32-bit value. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change the element type of the `ai_fifo_buffer[]` element of `struct ni_board_struct` and the types of various local variables from `short` to `unsigned short` for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change the type of the `data` variable in `labpc_ai_cmd()` from `short` to `unsigned short` for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented by unsigned values. Change the type of the `dma_buffer` member of `struct a2150_private` from `s16 *` to `uint16_t *`, and change the type of the `dpnt` variable in `a2150_interrupt()` to `unsigned short` for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change the types of various variables in the "me4000" driver dealing with samples to use unsigned types for consistency. Also replace the `long` or `unsigned long` variables used to handle 32-bit register values to `unsigned int`. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change the element type of the `ao_data[]` member of `struct icp_multi_private` from `short` to `unsigned short` for consistency. Also remove the `ai_data` and `di_data` members as they are not used. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change the element type of the `ao_readback[]` member of `struct fl512_private` from `short` to `unsigned short` for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change the type of the `data` variable in `dt3k_ai_empty_fifo()` from `short` to `unsigned short` for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change various members of `struct dt282x_private` and various parameters and variables dealing with samples to use `unsigned short` instead of `short` for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented by unsigned values. Change the type of the `ao_update_bits` member of `struct das1800_private` and the types of various local variables used to hold sample values from `short` to `unsigned short` for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change the element type of the `ai_buffer[]` member of `struct das16m1_private_struct` and the types used by `munge_sample()` and `munge_sample_array()` from `short` to `unsigned short` for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change the type of the `data` variable in `das16_ai_munge()` from `short *` to `unsigned short *` for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are unsigned. Change the element type of `ao_bounce_buffer[]` in `struct pcidas64_private` from `short` to `unsigned short` for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented by unsigned values. Change the element types of `ai_buffer[]`, `ao_buffer[]` and `ao_value[]` in `struct cb_pcidas_private` to `unsigned short` for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Replace all uses of `short` to handle sample values in the "amplc_pci230" driver with `unsigned short` for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change the type of the `ao_scan_vals` member of `struct pci224_private` from `short *` to `unsigned short *` for consistency. Also change the type of the `array` variable in `pci224_ao_munge()` from `short *` to `unsigned short *`. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change the element type of the `ao_data[]` member of `struct pci1723_private` from `short` to `unsigned short` for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change the element type of the `ao_data[]` member of `struct pci1710_private` from `short` to `unsigned short` for consistency. Also remove the `ai_data` member as it is only assigned to. Change various local variables used to hold sample values to `unsigned short`. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change the `ao_data[]` and `dmabuf_virt[]` members of `struct pci9118_private` and various local variables dealing with sample values to use `unsigned short` instead of `short` for consistency. Also remove the `short *ai_data` member of `struct pci9118_private` as it is only assigned to. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change the element type of the `ai_bounce_buffer[]` member of `struct pci9111_private_data` from `short` to `unsigned short` for consistency. Also change the type of the `array` variable in `pci9111_ai_munge()` from `short *` to `unsigned short *`. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. Change the element type of `ul_DmaBufferVirtual[2]` in `struct addi_private` from `short *` to `unsigned short *` for consistency. Note that several ADDI-DATA drivers use this struct from "addi_common.h", but only the "addi_apci_3120" driver uses this member. Also change the type of the `dma_buffer` parameter of `v_APCI3120_InterruptDmaMoveBlock16bit()` from `short *` to `unsigned short *`. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. `subdev_8255_interrupt()` calls `comedi_buf_put()` with a `short` data value merely because that's what was previously expected. Since it now expects an `unsigned short`, change it here for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. `cfc_write_to_buffer()` in "comedi_fc.h" currently uses `short` to hold a 16-bit sample value to be written to the buffer. Change the type of the parameter to `unsigned short` for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-
Ian Abbott authored
Sample values in comedi are generally represented as unsigned values. `comedi_buf_put()` and `comedi_buf_get()` use a `short` to hold the 16-bit data value being transferred to or from the comedi buffer. Change them to use `unsigned short` for consistency. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-