- 25 Jul, 2016 13 commits
-
-
Thierry Reding authored
-
Thierry Reding authored
-
Thierry Reding authored
-
Thierry Reding authored
-
Thierry Reding authored
-
Thierry Reding authored
-
Boris Brezillon authored
Document the pwm-dutycycle-unit and pwm-dutycycle-range properties. Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com> Acked-by: Brian Norris <briannorris@chromium.org> Acked-by: Rob Herring <robh@kernel.org> Acked-by: Mark Brown <broonie@kernel.org> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Boris Brezillon authored
The continuous mode allows one to declare a PWM regulator without having to declare the voltage <-> dutycycle association table. It works fine as long as your voltage(dutycycle) function is linear, but also has the following constraints: - dutycycle for min_uV = 0% - dutycycle for max_uV = 100% - dutycycle for min_uV < dutycycle for max_uV While the linearity constraint is acceptable for now, we sometimes need to restrict of the PWM range (to limit the maximum/minimum voltage for example) or have a min_uV_dutycycle > max_uV_dutycycle (this could be tweaked with PWM polarity, but not all PWMs support inverted polarity). Add the pwm-dutycycle-range and pwm-dutycycle-unit DT properties to define such constraints. If those properties are not defined, the PWM regulator use the default pwm-dutycycle-range = <0 100> and pwm-dutycycle-unit = <100> values (existing behavior). Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com> Reviewed-by: Brian Norris <briannorris@chromium.org> Tested-by: Brian Norris <briannorris@chromium.org> Tested-by: Heiko Stuebner <heiko@sntech.de> Acked-by: Mark Brown <broonie@kernel.org> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Brian Norris authored
Use the new ChromeOS EC EC_CMD_PWM_{GET,SET}_DUTY commands to control one or more PWMs attached to the Embedded Controller. Because the EC allows us to modify the duty cycle (as a percentage, where U16_MAX is 100%) but not the period, we assign the period a fixed value of EC_PWM_MAX_DUTY and reject all attempts to change it. This driver supports only device tree at the moment, because that provides a very flexible way of describing the relationship between PWMs and their consumer devices (e.g., backlight). On a non-DT system, we'll probably want to use the non-GENERIC addressing (i.e., we'll need to make special device instances that will use EC_PWM_TYPE_KB_LIGHT or EC_PWM_TYPE_DISPLAY_LIGHT), as well as the relatively inflexible pwm_lookup infrastructure for matching devices. Defer that work for now. Signed-off-by: Brian Norris <briannorris@chromium.org> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Brian Norris authored
The ChromeOS Embedded Controller can support controlling its attached PWMs via its host-command interface. The number of supported PWMs varies on a per-board basis, but we can autodetect this by checking the error codes, so we don't need an extra property for this. And because the EC only allows specifying the duty cycle and not the period, we don't specify the period via pwm-cells, and instead have only support for one cell -- to specify the index. Signed-off-by: Brian Norris <briannorris@chromium.org> Acked-by: Rob Herring <robh@kernel.org> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Thierry Reding authored
-
Brian Norris authored
The EC_CMD_PWM_{GET,SET}_DUTY commands allow us to control a PWM that is attached to the EC, rather than the main host SoC. The API provides functionality-based (e.g., keyboard light, backlight) or index-based addressing of the PWM(s). Duty cycles are represented by a 16-bit value, where 0 maps to 0% duty cycle and U16_MAX maps to 100%. The period cannot be controlled. This command set is more generic than, e.g., EC_CMD_PWM_{GET,SET}_KEYBOARD_BACKLIGHT and could possibly used to replace it on future products. Let's update the command header to include the definitions. Signed-off-by: Brian Norris <briannorris@chromium.org> Acked-by: Lee Jones <lee.jones@linaro.org> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Tomeu Vizoso authored
So that callers of cros_ec_cmd_xfer() don't have to repeat boilerplate code when checking for errors from the EC side. Signed-off-by: Tomeu Vizoso <tomeu.vizoso@collabora.com> Reviewed-by: Benson Leung <bleung@chromium.org> Signed-off-by: Brian Norris <briannorris@chromium.org> Acked-by: Lee Jones <lee.jones@linaro.org> Tested-by: Enric Balletbo i Serra <enric.balletbo@collabora.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
- 11 Jul, 2016 27 commits
-
-
Thierry Reding authored
Use of_device_get_match_data() instead of an open-coded variant. Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Thierry Reding authored
Avoid an overly long line by moving a comment around, and remove a use of else-after-return. Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Guillermo Rodriguez authored
When disabling a PWM channel, the PWM clock was being stopped immediately after writing to PWM_DIS. As a result, the disabling of the PWM channel did not complete properly, and the PWM output might be left at the wrong level. Fix this by waiting for the channel to be effectively disabled (by checking the PWM_SR register) before disabling the clock. Signed-off-by: Guillermo Rodriguez <guille.rodriguez@gmail.com> Acked-by: Alexandre Belloni <alexandre.belloni@free-electrons.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Ulrich Hecht authored
Add device tree bindings for the PWM controller found on R-Car H3 SoCs. The controller is compatible with the one found in earlier generations of R-Car SoCs. Signed-off-by: Ulrich Hecht <ulrich.hecht+renesas@gmail.com> Acked-by: Geert Uytterhoeven <geert+renesas@glider.be> Acked-by: Simon Horman <horms+renesas@verge.net.au> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Ryo Kodama authored
Replace ARCH_RCAR_GEN{1,2} with ARCH_RENESAS in order to support R-Car Gen3. Signed-off-by: Ryo Kodama <ryo.kodama.vz@renesas.com> Signed-off-by: Harunobu Kurokawa <harunobu.kurokawa.dn@renesas.com> Signed-off-by: Ulrich Hecht <ulrich.hecht+renesas@gmail.com> Acked-by: Geert Uytterhoeven <geert+renesas@glider.be> Acked-by: Simon Horman <horms+renesas@verge.net.au> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Laxman Dewangan authored
Tegra186 has multiple PWM controllers with only one output instead of one controller with four outputs in earlier SoC generations. Add support for Tegra186 and detect the number of PWM outputs using device tree match data. Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com> Reviewed-by: Alexandre Courbot <acourbot@nvidia.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Laxman Dewangan authored
Tegra186 has 8 different PWM controllers and each controller has only one output. Earlier SoC generations have 4 PWM outputs per controller. Add a device tree compatible string for Tegra186 to be able to differentiate between the two. Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Hyong Bin Kim authored
duty_ns * (1 << PWM_DUTY_WIDTH) could overflow in integer calculation when the PWM rate is low. Hence do all calculation on unsigned long long to avoid overflow. Signed-off-by: Hyong Bin Kim <hyongbink@nvidia.com> Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Victor(Weiguo) Pan authored
To get 100 % duty cycle (always high), pulse width needs to be set to 256. Signed-off-by: Victor(Weiguo) Pan <wpan@nvidia.com> Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Rohith Seelaboyina authored
Add reset control of the PWM controller to reset it before accessing the PWM register. Signed-off-by: Rohith Seelaboyina <rseelaboyina@nvidia.com> Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Thierry Reding authored
The former is much longer to type and is ambiguous because the value stored in the field is not the (physical) base address of the memory- mapped I/O registers, but the virtual address of those registers as mapped through the MMU. Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Thierry Reding authored
Use single spaces to separate data type from field names in structure definitions. Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Thierry Reding authored
This macro is used to initialize the ->npwm field of the PWM chip. Use a literal instead and make all other places rely on ->npwm. Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Sylvain Lemieux authored
The PWM_PIN_LEVEL bit is leave unset by the kernel PWM driver. Prior to commit 08ee77b5, the PWM_PIN_LEVEL bit was always clear when the PWM was disable and a 0 logic level was apply to the output. According to the LPC32x0 User Manual [1], the default value for bit 30 (PWM_PIN_LEVEL) is 0. This change initialize the pin level to 0 (default value) and update the register value accordingly. [1] http://www.nxp.com/documents/user_manual/UM10326.pdfSigned-off-by: Sylvain Lemieux <slemieux@tycoint.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Linus Walleij authored
This adds a driver for the PWM block found in chips of the STMPE 24xx series of multi-purpose I2C expanders. (I think STMPE means ST Microelectronics Multi-Purpose Expander.) This PWM was designed in accordance with Nokia specifications and is kind of weird and usually just switched between max and zero duty cycle. However it is indeed a PWM so it needs to live in the PWM subsystem. This PWM is mostly used for white LED backlight. Cc: Lee Jones <lee.jones@linaro.org> Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Linus Walleij authored
This adds fairly standard device tree bindings for the STMPE PWM found in STMPE24xx multi-purpose expanders. Cc: devicetree@vger.kernel.org Acked-by: Rob Herring <robh@kernel.org> Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Boris Brezillon authored
Implement the ->apply() function to add support for atomic update. Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com> Tested-by: Heiko Stuebner <heiko@sntech.de> Reviewed-by: Brian Norris <briannorris@chromium.org> Tested-by: Brian Norris <briannorris@chromium.org> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Boris Brezillon authored
The current logic will disable the PWM clk even if the PWM was left enabled by the bootloader (because it's controlling a critical device like a regulator for example). Keep the PWM clk enabled if the PWM is enabled to avoid any glitches. Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com> Reviewed-by: Brian Norris <briannorris@chromium.org> Tested-by: Brian Norris <briannorris@chromium.org> Tested-by: Heiko Stuebner <heiko@sntech.de> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Boris Brezillon authored
Implement the ->get_state() function to expose initial state. Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com> Reviewed-by: Brian Norris <briannorris@chromium.org> Tested-by: Brian Norris <briannorris@chromium.org> Tested-by: Heiko Stuebner <heiko@sntech.de> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Boris Brezillon authored
The current implementation always round down the duty and period values, while it would be better to round them to the closest integer. These changes are needed in preparation of atomic update support to prevent a period/duty cycle drift when executing several times the 'pwm_get_state() / modify / pwm_apply_state()' sequence. Say you have an expected period of 3.333 us and a clk rate of 112.666667 MHz -- the clock frequency doesn't divide evenly, so the period (stashed in nanoseconds) shrinks when we convert to the register value and back, as follows: pwm_apply_state(): register = period * 112666667 / 1000000000; pwm_get_state(): period = register * 1000000000 / 112666667; or in other words: period = period * 112666667 / 1000000000 * 1000000000 / 112666667; which yields a sequence like: 3333 -> 3328 3328 -> 3319 3319 -> 3310 3310 -> 3301 3301 -> 3292 3292 -> ... (etc) ... With this patch, we'd see instead: period = div_round_closest(period * 112666667, 1000000000) * 1000000000 / 112666667; which yields a stable sequence: 3333 -> 3337 3337 -> 3337 3337 -> ... (etc) ... Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com> Reviewed-by: Brian Norris <briannorris@chromium.org> Tested-by: Brian Norris <briannorris@chromium.org> Tested-by: Heiko Stuebner <heiko@sntech.de> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Yendapally Reddy Dhananjaya Reddy authored
Add support for the PWM controller present in Broadcom's iProc family of SoCs. It has been tested on the Northstar+ bcm958625HR board. Signed-off-by: Yendapally Reddy Dhananjaya Reddy <yendapally.reddy@broadcom.com> [thierry.reding@gmail.com: bunch of coding style fixes, cleanups] Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Yendapally Reddy Dhananjaya Reddy authored
Add a device tree binding for Broadcom iProc PWM controller. Signed-off-by: Yendapally Reddy Dhananjaya Reddy <yendapally.reddy@broadcom.com> Acked-by: Rob Herring <robh@kernel.org> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Andy Shevchenko authored
There is no need to check each time if the clk_rate defined or not when we call pwm_lpss_config(). Move the check to ->probe() instead. Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Andy Shevchenko authored
Intel Edison has 4 PWM channels on the die with the same IP as in Broxton. Enable it. Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Mika Westerberg authored
If duty_ns is large enough multiplying it by 255 overflows and results wrong duty cycle value being programmed. For example with 10ms duty when period is 20ms (50%) we get 255 * 10000000 / 20000000 = -87 because 255 * 10000000 overlows int. Whereas correct value should be 255 * 10000000 / 20000000 = 127 Fix this by using unsigned long long as type for on_time_div and changing integer literals to use proper type annotation. Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Dan O'Donovan authored
The base_unit calculation applies an offset of 0x2 which adds significant error for lower frequencies and doesn't appear to be warranted - rounding the division result gives a correct value. Also, the upper limit check for base_unit is off-by-one; the upper nibble of base_unit is invalid if >=128 according to the Table 88 in the Z8000 Processor Series Datasheet Volume 1 (Rev. 2). Verified on UP Board (Cherry Trail) and Minnowboard Max (Bay Trail). Signed-off-by: Dan O'Donovan <dan@emutex.com> Acked-by: Mika Westerberg <mika.westerberg@linux.intel.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-
Cooper Jr., Franklin authored
The PWMSS local clock gating registers have no real purpose on OMAP ARM devices. These registers were left over registers from DSP IP where the PRCM doesn't exist. There is a silicon bug where gating and ungating clocks don't function properly. TRMs will be update to indicate that these registers shouldn't be touched. Therefore, all code that accesses the PWMSS_CLKCONFIG or PWMSS_CLKSTATUS will be removed by this patch with zero loss of functionality by the ECAP and EPWM drivers. Signed-off-by: Franklin S Cooper Jr <fcooper@ti.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
-