- 31 Jul, 2012 40 commits
-
-
Sage Weil authored
If the connect() call immediately fails such that sock == NULL, we still need con_close_socket() to reset our socket state to CLOSED. Signed-off-by: Sage Weil <sage@inktank.com> Reviewed-by: Alex Elder <elder@inktank.com>
-
Sage Weil authored
* shiny new inktank.com email addresses * add include/linux/crush directory (previous oversight) Signed-off-by: Sage Weil <sage@inktank.com> Reviewed-by: Alex Elder <elder@inktank.com>
-
Sage Weil authored
There are many (normal) conditions that can lead to us getting unexpected replies, include cluster topology changes, osd failures, and timeouts. There's no need to spam the console about it. Signed-off-by: Sage Weil <sage@inktank.com> Reviewed-by: Alex Elder <elder@inktank.com>
-
Sage Weil authored
Signed-off-by: Sage Weil <sage@inktank.com>
-
Sage Weil authored
Rename flags with CON_FLAG prefix, move the definitions into the c file, and (better) document their meaning. Signed-off-by: Sage Weil <sage@inktank.com>
-
Sage Weil authored
Use a simple set of 6 enumerated values for the socket states (CON_STATE_*) and use those instead of the state bits. All of the con->state checks are now under the protection of the con mutex, so this is safe. It also simplifies many of the state checks because we can check for anything other than the expected state instead of various bits for races we can think of. This appears to hold up well to stress testing both with and without socket failure injection on the server side. Signed-off-by: Sage Weil <sage@inktank.com>
-
Sage Weil authored
If we are CLOSED, the socket is closed and we won't get these. Signed-off-by: Sage Weil <sage@inktank.com>
-
Sage Weil authored
It is simpler to do this immediately, since we already hold the con mutex. It also avoids the need to deal with a not-quite-CLOSED socket in con_work. Signed-off-by: Sage Weil <sage@inktank.com>
-
Sage Weil authored
If the state is CLOSED or OPENING, we shouldn't have a socket. Signed-off-by: Sage Weil <sage@inktank.com>
-
Sage Weil authored
Take the con mutex before checking whether the connection is closed to avoid racing with someone else closing it. Signed-off-by: Sage Weil <sage@inktank.com>
-
Sage Weil authored
Avoid dropping and retaking con->mutex in the ceph_con_send() case by leaving locking up to the caller. Signed-off-by: Sage Weil <sage@inktank.com>
-
Sage Weil authored
If we fault on a lossy connection, we should still close the socket immediately, and do so under the con mutex. We should also take the con mutex before printing out the state bits in the debug output. Signed-off-by: Sage Weil <sage@inktank.com>
-
Alex Elder authored
rbd_req_sync_unwatch() only ever uses rbd_dev->header_name as the value of its "object_name" parameter, and that value is available within the function already. So get rid of the parameter. Signed-off-by: Alex Elder <elder@inktank.com> Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
-
Alex Elder authored
rbd_req_sync_notify_ack() only ever uses rbd_dev->header_name as the value of its "object_name" parameter, and that value is available within the function already. So get rid of the parameter. Signed-off-by: Alex Elder <elder@inktank.com> Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
-
Alex Elder authored
rbd_req_sync_notify() only ever uses rbd_dev->header_name as the value of its "object_name" parameter, and that value is available within the function already. So get rid of the parameter. Signed-off-by: Alex Elder <elder@inktank.com> Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
-
Alex Elder authored
rbd_req_sync_watch() is only called in one place, and in that place it passes rbd_dev->header_name as the value of the "object_name" parameter. This value is available within the function already. Having the extra parameter leaves the impression the object name could take on different values, but it does not. So get rid of the parameter. We can always add it back again if we find we want to watch some other object in the future. Signed-off-by: Alex Elder <elder@inktank.com> Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
-
Alex Elder authored
Both rbd_register_snap_dev() and __rbd_remove_snap_dev() have rbd_dev parameters that are unused. Remove them. Signed-off-by: Alex Elder <elder@inktank.com> Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
-
Alex Elder authored
The function rbd_header_from_disk() is only called in one spot, and it passes GFP_KERNEL as its value for the gfp_flags parameter. Just drop that parameter and substitute GFP_KERNEL everywhere within that function it had been used. (If we find we need the parameter again in the future it's easy enough to add back again.) Signed-off-by: Alex Elder <elder@inktank.com> Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
-
Alex Elder authored
The "snapc" parameter to in rbd_req_sync_read() is not used, so get rid of it. Reported-by: Josh Durgin <josh.durgin@inktank.com> Signed-off-by: Alex Elder <elder@inktank.com> Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
-
Alex Elder authored
The "id" field of an rbd device structure represents the unique client-local device id mapped to the underlying rbd image. Each rbd image will have another id--the image id--and each snapshot has its own id as well. The simple name "id" no longer conveys the information one might like to have. Rename the device "id" field in struct rbd_dev to be "dev_id" to make it a little more obvious what we're dealing with without having to think more about context. Signed-off-by: Alex Elder <elder@inktank.com> Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
-
Alex Elder authored
If an rbd image header is read and it doesn't begin with the expected magic information, a warning is displayed. This is a fairly simple test, but it could be extended at some point. Fix the comparison so it actually looks at the "text" field rather than the front of the structure. In any case, encapsulate the validity test in its own function. Signed-off-by: Alex Elder <elder@inktank.com> Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
-
Alex Elder authored
There are two structures in which a count of snapshots are maintained: struct ceph_snap_context { ... u32 num_snaps; ... } and struct ceph_snap_realm { ... u32 num_prior_parent_snaps; /* had prior to parent_since */ ... u32 num_snaps; ... } These fields never take on negative values (e.g., to hold special meaning), and so are really inherently unsigned. Furthermore they take their value from over-the-wire or on-disk formatted 32-bit values. So change their definition to have type u32, and change some spots elsewhere in the code to account for this change. Signed-off-by: Alex Elder <elder@inktank.com> Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
-
Alex Elder authored
There was a dout() call in rbd_do_request() that was reporting the reporting the offset as the length and vice versa. While fixing that I did a quick scan of other dout() calls and fixed a couple of other minor things. Signed-off-by: Alex Elder <elder@inktank.com> Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
-
Alex Elder authored
This just replaces a while loop with list_for_each_entry_safe() in __rbd_remove_all_snaps(). Signed-off-by: Alex Elder <elder@inktank.com> Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
-
Alex Elder authored
In commit c666601a there was inadvertently added an extra initialization of rbd_dev->header_rwsem. This gets rid of the duplicate. Reported-by: Guangliang Zhao <gzhao@suse.com> Signed-off-by: Alex Elder <elder@inktank.com> Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
-
Alex Elder authored
The snap_seq field in an rbd_image_header structure held the value from the rbd image header when it was last refreshed. We now maintain this value in the snapc->seq field. So get rid of the other one. Signed-off-by: Alex Elder <elder@inktank.com> Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
-
Alex Elder authored
In rbd_header_add_snap() there is code to set snapc->seq to the just-added snapshot id. This is the only remnant left of the use of that field for recording which snapshot an rbd_dev was associated with. That functionality is no longer supported, so get rid of that final bit of code. Doing so means we never actually set snapc->seq any more. On the server, the snapshot context's sequence value represents the highest snapshot id ever issued for a particular rbd image. So we'll make it have that meaning here as well. To do so, set this value whenever the rbd header is (re-)read. That way it will always be consistent with the rest of the snapshot context we maintain. Signed-off-by: Alex Elder <elder@inktank.com> Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
-
Alex Elder authored
In rbd_header_set_snap(), there is logic to make the snap context's seq field get set to a particular snapshot id, or 0 if there is no snapshot for the rbd image. This seems to be an artifact of how the current snapshot id for an rbd_dev was recorded before the rbd_dev->snap_id field began to be used for that purpose. There's no need to update the value of snapc->seq here any more, so stop doing it. Tidy up a few local variables in that function while we're at it. Signed-off-by: Alex Elder <elder@inktank.com> Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
-
Alex Elder authored
In what appears to be an artifact of a different way of encoding whether an rbd image maps a snapshot, __rbd_refresh_header() has code that arranges to update the seq value in an rbd image's snapshot context to point to the first entry in its snapshot array if that's where it was pointing initially. We now use rbd_dev->snap_id to record the snapshot id--using the special value CEPH_NOSNAP to indicate the rbd_dev is not mapping a snapshot at all. There is therefore no need to check for this case, nor to update the seq value, in __rbd_refresh_header(). Just preserve the seq value that rbd_read_header() provides (which, at the moment, is nothing). Signed-off-by: Alex Elder <elder@inktank.com> Reviewed-by: Josh Durgin <josh.durgin@inktank.com>
-
Josh Durgin authored
Previously the original header version was sent. Now, we update it when the header changes. Signed-off-by: Josh Durgin <josh.durgin@dreamhost.com> Reviewed-by: Alex Elder <elder@inktank.com>
-
Josh Durgin authored
This prevents a race between requests with a given snap context and header updates that free it. The osd client was already expecting the snap context to be reference counted, since it get()s it in ceph_osdc_build_request and put()s it when the request completes. Also remove the second down_read()/up_read() on header_rwsem in rbd_do_request, which wasn't actually preventing this race or protecting any other data. Signed-off-by: Josh Durgin <josh.durgin@dreamhost.com> Reviewed-by: Alex Elder <elder@inktank.com>
-
Josh Durgin authored
The image may have been resized. Signed-off-by: Josh Durgin <josh.durgin@dreamhost.com> Reviewed-by: Alex Elder <elder@inktank.com>
-
Josh Durgin authored
If an image was mapped to a snapshot, the size of the head version would be shown. Protect capacity with header_rwsem, since it may change. Signed-off-by: Josh Durgin <josh.durgin@dreamhost.com> Reviewed-by: Alex Elder <elder@inktank.com>
-
Josh Durgin authored
Snapshots cannot be resized, and the new capacity of head should not be reflected by the snapshot. Signed-off-by: Josh Durgin <josh.durgin@inktank.com> Reviewed-by: Alex Elder <elder@inktank.com>
-
Josh Durgin authored
When a snapshot is deleted, the OSD will return ENOENT when reading from it. This is normally interpreted as a hole by rbd, which will return zeroes. To minimize the time in which this can happen, stop requests early when we are notified that our snapshot no longer exists. [elder@inktank.com: updated __rbd_init_snaps_header() logic] Signed-off-by: Josh Durgin <josh.durgin@inktank.com> Reviewed-by: Alex Elder <elder@inktank.com>
-
Jiaju Zhang authored
This is a trivial fix for the debug output, as it is inconsistent with the function name so may confuse people when debugging. [elder@inktank.com: switched to use __func__] Signed-off-by: Jiaju Zhang <jjzhang@suse.de> Reviewed-by: Alex Elder <elder@inktank.com>
-
Alan Cox authored
We re-run the loop but we don't re-set the attrs pointer back to NULL. Signed-off-by: Alan Cox <alan@linux.intel.com> Reviewed-by: Alex Elder <elder@inktank.com>
-
Sage Weil authored
We exponentially back off when we encounter connection errors. If several errors accumulate, we will eventually wait ages before even trying to reconnect. Fix this by resetting the backoff counter after a successful negotiation/ connection with the remote node. Fixes ceph issue #2802. Signed-off-by: Sage Weil <sage@inktank.com> Reviewed-by: Yehuda Sadeh <yehuda@inktank.com> Reviewed-by: Alex Elder <elder@inktank.com>
-
Sage Weil authored
Take the con mutex while we are initiating a ceph open. This is necessary because the may have previously been in use and then closed, which could result in a racing workqueue running con_work(). Signed-off-by: Sage Weil <sage@inktank.com> Reviewed-by: Yehuda Sadeh <yehuda@inktank.com> Reviewed-by: Alex Elder <elder@inktank.com>
-
Sage Weil authored
When we detect a mds session reset, close the old ceph_connection before reopening it. This ensures we clean up the old socket properly and keep the ceph_connection state correct. Signed-off-by: Sage Weil <sage@inktank.com> Reviewed-by: Alex Elder <elder@inktank.com> Reviewed-by: Yehuda Sadeh <yehuda@inktank.com>
-