Bug #46828 rpl_get_master_version_and_clock fails on PB-2
The 'rpl_get_master_version_and_clock' test verifies if the slave I/O thread tries to reconnect to master when it tries to get the values of the UNIX_TIMESTAMP, SERVER_ID from master under network disconnection. So the master server is restarted for making the transient network disconnection. Restarting master server can bring two problems as following: 1. The time out error is encountered sporadically. The slave I/O thread tries to reconnect master ten times, which is set in my.cnf. So in the test framework sporadically the slave I/O thread really stoped when it can't reconnect to master in the ten times successfully before the master starts, then the time out error will be encountered while waiting for the slave to start. 2. These warnings and errors are produced in server log file when the slave I/O thread tries to get the values of the UNIX_TIMESTAMP, SERVER_ID from master under the transient network disconnection. To fix problem 1, increase the master retry count to sixty times, so that the slave I/O thread has enough time to reconnect master successfully. To fix problem 2, suppress these warnings and errors by mtr suppression, because they are expected. mysql-test/suite/rpl/t/rpl_get_master_version_and_clock-slave.opt: Added the *.opt file for increasing master retry count to sixty times. mysql-test/suite/rpl/t/rpl_get_master_version_and_clock.test: Added mtr suppression for suppressing warnings and errors in server log file.