MDEV-24270 Misuse of io_getevents() causes wake-ups at least twice per second
In the asynchronous I/O interface, InnoDB is invoking io_getevents() with a timeout value of half a second, and requesting exactly 1 event at a time. The reason to have such a short timeout is to facilitate shutdown. We can do better: Use an infinite timeout, wait for a larger maximum number of events. On shutdown, we will invoke io_destroy(), which should lead to the io_getevents system call reporting EINVAL. my_getevents(): Reimplement the libaio io_getevents() by only invoking the system call. The library implementation would try to elide the system call and return 0 immediately if aio_ring_is_empty() holds. Here, we do want a blocking system call, not 100% CPU usage. Neither do we want the aio_ring_is_empty() trigger SIGSEGV because it is dereferencing some memory that was freed by io_destroy().