AngeloGioacchino Del Regno authored
LAB and IBB regulators can be current-limited by setting the appropriate registers, but this operation is granted only after sending an unlock code for secure access. Besides the secure access, it would be possible to use the regmap helper for get_current_limit, as there is no security blocking reads, but I chose not to as to avoid having a very big array containing current limits, especially for IBB. That said, these regulators support current limiting for: - LAB (pos): 200-1600mA, with 200mA per step (8 steps), - IBB (neg): 0-1550mA, with 50mA per step (32 steps). Signed-off-by: AngeloGioacchino Del Regno <angelogioacchino.delregno@somainline.org> Link: https://lore.kernel.org/r/20210119174421.226541-3-angelogioacchino.delregno@somainline.orgSigned-off-by: Mark Brown <broonie@kernel.org>
8056704b