net: ethernet: renesas: rcar_gen4_ptp: Get clock increment from clock rate
Instead of using hard coded clock increment values for each SoC derive the clock increment from the module clock. This is done in preparation to support a second platform, R-Car V4H that uses a 200Mhz clock compared with the 320Mhz clock used on R-Car S4. Tested on both SoCs, S4 reports a clock of 320000000Hz which gives a value of 0x19000000. Documentation says a 320Mhz clock is used and the correct increment for that clock is 0x19000000. V4H reports a clock of 199999992Hz which gives a value of 0x2800001a. Documentation says a 200Mhz clock is used and the correct increment for that clock is 0x28000000. Suggested-by: Geert Uytterhoeven <geert@linux-m68k.org> Signed-off-by: Niklas Söderlund <niklas.soderlund+renesas@ragnatech.se> Reviewed-by: Simon Horman <horms@kernel.org> Signed-off-by: Paolo Abeni <pabeni@redhat.com>