Jaedon Shin authored
The BSC data buffers to send and receive data are each of size 32 bytes or 8 bytes 'xfersz' depending on SoC. The problem observed for all the combined message transfer was if length of data transfer was a multiple of 'xfersz' a repeated START was being transmitted by BSC driver. Fixed this by appropriately setting START/STOP conditions for such transfers. Fixes: dd1aa252 ("i2c: brcmstb: Add Broadcom settop SoC i2c controller driver") Signed-off-by: Jaedon Shin <jaedon.shin@gmail.com> Acked-by: Kamal Dasu <kdasu.kdev@gmail.com> Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
2de3ec4f